 marlow industries inc.(R)
Thermoelectric Cooler
Performance Values
Hot Side Temperature (C) Tmax (C-dry N2): Qmax (watts): Imax (amps): Vmax (vdc): AC Resistance (ohms): 27C 65 3.2 1.9 2.61 1.19 85C 86 4.0 1.8 3.31 ---
SP5083
Mechanical Characteristics
Positive Lead Leads: 30 AWG Buss Copper, Tin Over Nickel Negative Lead
.237 [6.02]
.322 [8.18]
2.00 .25 [50.80 6.35]
Cold Side, Tc .065 .004 [1.65 .10]
.004[0.10] A .001[0.03] .001[0.03]
Hot Side, Th Ceramic Material: Alumina (AC) Millimeters are in [ ]
Ordering Options
* SP5083-01 SP5083-02 SP5083-03 both surfaces are metallized hot side exterior is metallized no metallization
102-0220, Rev B
*
For example, and SP5083 with only the hot side metallized is specified as an SP5083-02AC Pretinned metallized ceramic surface(s) with 96C or 117C solder.
Thermoelectric Cooler
Performance Curves
Environment: One atmosphere dry nitrogen
TA(C)= 27 80.0 HEAT LOAD (WATTS) 0.00 0.25 0.50 0.75 1.00 1.25 1.50 1.75 2.00 2.25 2.50 2.75 3.00 100.0 80.0 60.0 40.0 20.0 0.0 TA(C)= 85
SP5083
60.0 T (C)
HEAT LOAD (WATTS) 0.00 0.50 1.00 1.50 2.00 2.50 3.00 3.50
40.0
20.0
0.0
VOLTAGE (VDC)
2.0
VOLTAGE (VDC)
3.0
T (C)
3.0
2.0
1.0
Q=0 T=0
0.4 0.8 1.2 1.6 CURRENT (AMPS) 2.0
1.0
Q=0 T=0
0.0 0.0
0.0 0.0
0.4
0.8 1.2 1.6 CURRENT (AMPS)
2.0
For performance information in a vacuum or with hot side temperatures other than 27C or 50C, consult one of our Applications Engineers.
Installation
Recommended mounting methods: Bonding with thermal epoxy or soldering with metallized ceramics. For additional information, please refer to our TEC Installation Guide.
Operation Cautions
For maximum reliability, storage and operation below 85C in a non-condensing environment is recommended. To minimize thermal stress, use linear/proportional temperature control or a similar method rather than an ON/OFF method.
Marlow Industries, Inc. 10451 Vista Park Road Dallas Texas 75238-1645 TEL: 214-340-4900 FAX: 214-341-5212 Internet: http://www.marlow.com
Marlow Industries Europe Aberdeen House, South Road Haywards Heath West Sussex RH164NG UK TEL: +44 (0)1444-443404 FAX: +44 (0)1444-443334
Marlow Industries Asia 1-1-8-401 Uehara, Shibuya-ku Tokyo, Japan 151-0064 TEL: +81 (3) 5454-5280 FAX: +81 (3) 5454-5281
Copyright 2000, Marlow Industries, Inc. Marlow Industries reserves the right to change the design and specifications of products without notice. 102-0220, Rev B


▲Up To Search▲   

 
Price & Availability of SP5083-01

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X